Red Seal Electrician Practice Exam (Canada)

15 CEC-based practice questions for the Red Seal 309A Construction Electrician exam. Each answer links to the relevant Canadian Electrical Code rule.

Score: 0 / 0(0/15 answered)
  1. Ampacity & ConductorsQuestion 1 of 15

    Per CEC Table 2, what is the allowable ampacity of a 3-conductor #6 AWG copper RW90 cable in a raceway at 30 °C ambient?

  2. Continuous LoadsQuestion 2 of 15

    When sizing conductors and overcurrent devices for a continuous load, the calculated load must be multiplied by:

  3. Voltage DropQuestion 3 of 15

    What is the maximum allowable voltage drop from the supply to the point of utilization for a typical branch circuit and feeder combined?

  4. Bonding & GroundingQuestion 4 of 15

    What minimum size copper bonding conductor is required for equipment supplied by a 100 A overcurrent device?

  5. Conduit FillQuestion 5 of 15

    Per CEC Table 8, what is the maximum percent fill of a conduit containing four or more conductors?

  6. ReceptaclesQuestion 6 of 15

    In a dwelling unit, GFCI protection is required for receptacles installed within what distance of the inside walls of a bathtub or shower stall?

  7. Box FillQuestion 7 of 15

    When calculating box fill, each insulated conductor passing through the box without splice counts as:

  8. TransformersQuestion 8 of 15

    For a dry-type transformer rated more than 9 kVA, what is the maximum primary OCPD rating when no secondary protection is provided?

  9. MotorsQuestion 9 of 15

    Per CEC Rule 28-106, conductors supplying a single continuous-duty motor shall have an ampacity not less than:

  10. Service SizingQuestion 10 of 15

    What is the minimum service or feeder ampacity for a single dwelling with a floor area over 80 m² and electric range?

  11. AFCI ProtectionQuestion 11 of 15

    Branch circuits supplying receptacles in dwelling bedrooms must be protected by:

  12. Working SpaceQuestion 12 of 15

    The minimum headroom required in front of electrical equipment likely to require examination while energized is:

  13. Demand FactorsQuestion 13 of 15

    For a single dwelling, the demand factor applied to the basic load above 10 kW (rule 8-200) is:

  14. Outdoor ReceptaclesQuestion 14 of 15

    Outdoor receptacles in single dwellings must be:

  15. Conductor TerminationQuestion 15 of 15

    When equipment is marked for 75 °C terminations, conductor ampacity is based on the: